JB Medical Supplies

JB Medical Supplies
JB Medical Supplies
Health Service & Doctors-ALBION, QLD
Health Service & Doctors-Albion, QLD
ROM Plus Fetal Membranes Rupture Test is a rapid, qualitative test for the in vitro detection of amniotic fluid in vaginal secretions of pregnant women. It utilizes a combination of monoc..
PO Box 255, Albion, Qld, 4010.
PO Box 255, Albion, Qld, 4010.
Is this your business? Claim
Ratings & Reviews
Write Review
Write a review for JB Medical Supplies
Hide Review
"How is you experience with JB Medical Supplies ? Let others know.."
Images & Videos:
ROM Plus Fetal Membranes Rupture Test is a rapid, qualitative test for the in vitro detection of amniotic fluid in vaginal secretions of pregnant women. It utilizes a combination of monoclonal and polyclonal antibodies to detect alpha-fetoprotein (AFP) and placental protein 12 (PP12), or insulin growth factor binding protein-1 (IGFPB-1) found in amniotic fluid.
Kiwi OmniCup MT & M

The Kiwi vacuum assisted fetal delivery device is an integral unit designed for complete control in the hands of the operator without the need of an assistant to operate the pump.

The Kiwi OmniCup MT incorporates a Traction Force Indicator that displays the force exerted on the fetal head whereas the OmniCup M does not have an indicator. The OmniCup is designed for use in all fetal head positions- occiput anterior, occiput posterior and occiput transverse - as well as for delivery of the head at caesarean section.

The PalmPump™ provides a safe and effective vacuum system in the palm of your hand. 

There is also a Kiwi soft cup device - the Kiwi ProCup that has been designed for use in low occiput anterior and outlet procedures. 


Ordering Information


Product InformationTOP OF PAGE
Its flexible stem and low-profile cup enable proper placement, helping to reduce ¨pop offs.¨ The OmniCup is a complete vacuum-assisted fetal delivery device disigned for use in all fetal head positions. Its flexible stem and low-profile cup enable placement over the flexion point (see below) so that the smallest diameters of the fetal head are presented to the birth canal.

The Traction Force Indicator measures the force exerted during traction. Two models of the OmniCup are available, with or without the Traction Force Indicator.

Simple

The Kiwi OmniCup features a low profile and stem-free traction mechanism that make it possible to place the cup safely and correctly over the flexion point of the fetal head (3cm forward of posterior fontanelle).
Versatile

When the OmniCup is properly placed and traction is exerted in line with the pelvic axis, malpositions of the fetal head can be corrected so that the optimal diameters present to the birth canal and autorotation can occur naturally.
Social Info:



Loading...
Explore Near By or Similar Business: